The test load applied is 1.5 times the safe carrying capacity of the pile. The Maintained load method as described in Clause 6.2 of IS-2911 (Part IV) – 1985 shall befollowed for loading for the Routine Tests.
This test will be performed for the following purposes:
To ensure the safe load capacity of piles.
Detection of any unusual performance contrary to the findings of the Initial Test.